Hex Code: | 43 | 00 | 00 | 0S | 00 | RR | 00 | 00 |   unconditional, indirect |
---|---|---|---|---|---|---|---|---|---|
43 | M0 | 00 | 0S | 00 | RR | XX | YY |   M=1-7, Compare register XX to register YY, indirect | |
43 | 0K | 00 | 0S | 00 | RR | HH | LL |   unconditional, indirect, K=1,4-7 Set then Link | |
53 | 00 | SS | SS | 00 | RR | 00 | 00 |   unconditional, direct | |
53 | M0 | SS | SS | 00 | RR | XX | YY |   M=1-7, Compare register XX to register YY, direct | |
53 | 0K | SS | SS | 00 | RR | HH | LL |   unconditional, direct, K=1,4-7 Set then Link |
Action: | The SetGPRMMD sets a GPRM value and mode (counter or register).
A register in counter mode increments once per second. In all forms the destination GPRM number is in the lower 4 bits of "RR" (byte 5). Bit 7 of "RR" determines the mode, 0=register mode, 1=counter mode. The indirect form uses the value in the GPRM register indicated by "S" (lower nibble of byte 3). The direct form uses "SSSS" (bytes 2&3) as the value. If "K" is 1, 4, 5, 6, or 7 the Set is followed by a link command. |
Order: | If a compare is specified, it is performed first. If the condition is met the SetGPRMMD is executed. |
Comments: | The command can be conditional or be combined with a link command, but not both.
The source and destination register may be the same, used for changing the mode only. MOV is the only allowed operator of a set command with a GPRM in counter mode as the target. |
Optional Link Command details | |||
---|---|---|---|
K | LL | Link Command | Comment |
1 | 00 | LinkNoLink | use byte 6 as "HH" in these detailed pages, ignore all other values. |
1 | 01 | LinkTopCell | |
1 | 02 | LinkNextCell | |
1 | 03 | LinkPrevCell | |
1 | 05 | LinkTopPG | |
1 | 06 | LinkNextPG | |
1 | 07 | LinkPrevPG | |
1 | 09 | LinkTopPGC | |
1 | 0A | LinkNextPGC | |
1 | 0B | LinkPrevPGC | |
1 | 0C | LinkGoUpPGC | |
1 | 0D | LinkTailPGC | |
1 | 10 | RSM | |
4 | -- | LinkPGCN | use bytes 6 and 7 as "NNNN" in this detailed page, ignore all other values. |
5 | -- | LinkPTTN | use bytes 6 and 7 as "HTTT" in this detailed page, ignore all other values. |
6 | -- | LinkPGN | use bytes 6 and 7 as "HHPP" in this detailed page, ignore all other values. |
7 | -- | LinkCN | use bytes 6 and 7 as "HHNN" in this detailed page, ignore all other values. |
Compare operation codes | |||
---|---|---|---|
register to register | Alternate mnemonic | Comments | |
M | operation | ||
1 | RegX & RegY | BC | Bitwise compare, the two operands are anded, if the result is non-zero the condition is true |
2 | RegX == RegY | EQ | If the two operands are equal the condition is true |
3 | RegX != RegY | NE | If the two operands are not equal the condition is true |
4 | RegX >= RegY | GE | If RegX is greater than or equal to the right operand the condition is true |
5 | RegX > RegY | GT | If RegX is greater than the right operand the condition is true |
6 | RegX <= RegY | LE | If RegX is less than or equal to the right operand the condition is true |
7 | RegX < RegY | LT | If RegX is less than the right operand the condition is true |
Register Codes | |
---|---|
0x00 through 0x0F | General Purpose registers 0 to 15 (GPRM) |
0x80 through 0x97 | System Parameter registers 0 to 23 (SPRM) |
all others | do not use |
Numerically | Alphabetically | Index |
Alphabetically | Numerically |
DVD-Video info home | Copyright © 2001 - 2024 MPUCoder, all rights reserved. |